PRODUCT CODE IN018000 INFUSION SET FOR USE WITH PVC INCOMPATIBLE COMPOUNDS AND WITH STERILIZING I.V. SOLUTION FILTER 0.2 INFUSION SET COMPOSED OF: 1.1 Technical characteristics of the I.V. set:
• Protective cap: Maintains the sterility of the fluid path.
• Closure Piercing Device: The special design of the spike
enables easy penetration of bottle and plastic bag closures
• Air Inlet: With bacterial air filter and attached airway
• Drip Chamber: The flexible drip chamber can be quickly
and easily filled and the fluid set to the level at the ring
mark. The transparent non reflective material, of which it is
made, makes control of the adjusted flow rate very easy.
Standard drop rate 20 drops water = 1 ml. ± 0.1 ml.
• Flow Regulator: Patented precision roller clamp enables
exact adjustment of the desired flow rate and holds it there
• Tubing: Transparent PVC D.E.H.P. FREE tubing, i.d. 3.0
• Injection site: “Y” injection port, produced in isoprene
“LATEX FREE”, permits a secure additional medication.
• Needle adapter : Male Luer- Lock adapter guarantees a
secure connection to the venipuncture device ( I.V. catheter
CLASS: I Sterile
• Packaging: device packaged in sterile single blister. Box STERILIZING I.V. SOLUTION FILTER:
To use in the I.V. therapy. This filter is indicated for i.v.
administration solutions. It offers the possibility to maximise
Manufactured by
the use of I.V. set, and offers to the patient more protection
ARIES S.r.l.
from associates risks, than the standard I.V. set. Removes
Via XXV Luglio, 43 - 41037 Mirandola (MO) Italy microbial, particulate and air contamination. This filter with 0.2
The infusion set has been studied to allow the infusion of all PVC incompatible compounds through constantly dosages without drug’s lost. The device is produced in PVC without phthalate (DEHP) being plastified with TOTM (tri-2 etilesil-trimellitato), a primary plasticizer with high molecular weight, indicated for use with bags for blood preservation, dialysis tubing, catheters, extension set and other medical devices. These I.V. sets could be utilised with all "PVC incompatible compounds", such as Chlorpromazine HCL, Chlormethiazole, Diazepam, Dopamine HCL, Hydralazine, Isosorbide bi-nitrate, Promazine HCL, Promethazine HCL, Pyridoxine HCL, Taxol, Theophyilline, Thiofluorperazine, Thiopental sodium, Thioridazine HCL etc. The in line 0.2 micron filter makes the set particularly indicated for administration of “TAXOL” and for all those antineoplastic drugs for administration of which is necessary a set with similar characteristics to this one. 1.2 Technical characteristics of the filter:
• Maximum operating pressure 45 PSI (3.1 bar) • Air vented, to prevent filter blocks. • Several filling possibility. • Priming volume: 2.4 ml. • Effective filtration area: 10 cm² • Water bubble point: 3.1- 3.7 bar • Minimum water flow rate: > 20 mL/min. at 91 cm.
MATERIALS: • Filter Media: Supor (polyethersulfone) membrane 0,2 micron. • Housing: modified acrylic • Support: polyester • Biocompatibility: construction materials pass USP class VI-121° C plastic, hemolysis and cytotoxicity Staytime: according to needs of medical staff. Tests: Each component is tested with a dimensional and visual test to verify the conformity to the internal QA parameters. On the finished products, before of the sterilization, are conducted visual tests, dimensional, physical flowing and sealing. The sampling plan are studied according to UNI ISO 2859-1. On the finished products are conducted sterility tests, apirogenicity, biocompatibility and toxic according to ISO 10993. Infusional liquids compatibility: biological liquids compatible, blood and emoderivates, all organic and non-organic solutions. Production and conformity: This device is produced following the GMP. Moreover ARIES has build up a Quality System according to UNI EN ISO 9001: 2000 e UNI CEI EN ISO 13485: 2004. This device is conform to the directive 93/42/CEE and it’s biocompatible according to ISO 10993. Materials used are of medical grade and components are produced according to ISO 594/1-2. Corr. ed.,E.P.Corr. ed. Stocking: temperature from +5°C, up to +40°C. Sterilisation: ETO resistant. Expiry date 5 years from sterilisation date. Residue gas according to F.UI Corr. Ed.and F.E.Corr. Ed (10 ppm).
Winer et al. • Treatment of Hypoparathyroidism with PTH-(1–34)J Clin Endocrinol Metab, September 2003, 88(9):4214–4220 4219 TABLE 2. Mean BMD and BMC values in the two treatment groups a P value calculations were based on measurements at 0, 0.5, 1, 1.5, 2, 2.5, and 3 yr. b BMD, grams per square centimeter; BMC, grams. hypercalciuria in the calcitriol-treated group did not caus
York PotashProject (Pipeline): Appendix 9.10 - Botanical Species List APPENDIX 9.10 - BOTANICAL SPECIES LIST Scientific Name Common Name Locally abundant in woodland and other habitatsRare in less-improved permanent grasslands Anagallis arvensis subsp. arvensis Occasional in hedgerows and field marginsCommon in less-improved permanent pasturesYork PotashProject (Pipeline): Appendix 9