AMVAC CHEMICAL CORPORATION Page 1 of 8 AMBUSH® 25W AMVAC MSDS No.: 297_3 MATERIAL SAFETY DATA SHEET CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME:AMBUSH® 25W Insecticide Wettable Powder; AMBUSH® 25W Insecticide Water Soluble Pack GENERAL USE:Insecticide PRODUCT DESCRIPTION: Off-white powder EPA Registration Number: 5481-502; 5481-503 MSDS No.: 297_3 MSDS Revision Date: 21 October, 2005 MANUFACTURER: EMERGENCY TELEPHONE NUMBERS: AMVAC CHEMICAL CORPORATION MANUFACTURER: 323-264-3910 4100 E. Washington Blvd. TRANSPORTATION (24 HOURS) Los Angeles, CA 90023-4406 CHEMTREC: 800-424-9300 Ph: 323-264-3910 OTHER (24 HOURS) FAX: 323-268-1028 323-264-3910 COMPOSITION/INFORMATION ON INGREDIENTS COMPONENT Typical % OSHA HAZARDOUS COMPONENTS (29 CFR1910.1200)
AMBUSH is a registered trademark of a Syngenta Group Company. AMVAC CHEMICAL CORPORATION Page 2 of 8 AMBUSH® 25W AMVAC MSDS No.: 297_3 HAZARDS IDENTIFICATION EMERGENCY OVERVIEW: WARNING: May cause eye and skin irritation. Harmful if swallowed. Avoid inhaling dust. Do not contaminate feed or foodstuffs. KEEP OUT OF REACH OF CHILDREN. Toxic to fish and aquatic organisms. POTENTIAL HEALTH EFFECTS ROUTE(S) OF ENTRY: Ingestion, inhalation, eye contact, and skin contact. SIGNS OF ACUTE OVEREXPOSURE: A person suffering from acute exposure to this product may
suffer from mild eye irritation. In addition, exposure to Permethrin may induce adverse effectson the nervous system. Symptoms include hypersensitivity, tremors, unsteady gait, andsalivation. Other possible signs of overexposure include facial erythema (flushing) and facialskin tingling. SIGNS OF CHRONIC OVEREXPOSURE: Prolonged exposure to high atmospheric
concentrations of respirable dust of amorphous silica may cause non-progressive fibrosisof the lungs; amorphous silica does not cause silicosis. OTHER POTENTIAL HEALTH EFFECTS: No evidence of mutagenic or teratogenic potential has
been observed. EPA (2004) has evaluated the carcinogenic potential of Permethrin underits ‘Review Draft of the Guidelines fro Carcinogen Risk Assessment (1999)’. Permethrinhas suggestive evidence of carcinogenicity but not sufficient to assess humancarcinogenic potential. MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE: None known. CARE SHOULD BE EXERCISED IN HANDLING PERMETHRIN AND ITS FORMULATIONS FIRST AID MEASURES EYES: Immediately flush the eyes with copious amounts of clear, cool running water for a minimum
of 15 minutes. Hold the eyelids apart during the flushing to ensure rinsing of the entiresurface of the eyes and lids with water. Contact a physician immediately. If there will be adelay in getting medical attention, rinse the eyes for at least another 15 minutes. AMVAC CHEMICAL CORPORATION Page 3 of 8 AMBUSH® 25W AMVAC MSDS No.: 297_3 FIRST AID MEASURES, cont'd INHALATION: Remove victim to fresh air. If breathing has ceased, clear the victim's airway and
start artificial respiration, preferably mouth-to-mouth . If breathing is difficult, give oxygen. Contact a physician immediately. INGESTION: Induce vomiting immediately by giving two glasses of water and sticking a finger down
throat. Never give anything by mouth to an unconscious person. Contact a physicianimmediately. SKIN: Remove contaminated clothing. Wash thoroughly with soap and clean water. If a rash or any
of the symptoms of acute exposure appear, contact a physician immediately. NOTE TO PHYSICIANS: Treat symptomatically. For medical information contact your local, state
or national poison control center. For other questions AMVAC Chemical Corporation isavailable 24 hours/day to answer questions on this product. The telephone number is 1-323-264-3910. FIRE FIGHTING MEASURES FLAMMABLE PROPERTIES
Flammability: This product contains a combustible liquid that will support fire if it is
EXPLOSIVITY HAZARDOUS COMBUSTION PRODUCTS: This product may emit hazardous fumes of hydrogen
chloride, carbon oxides and unidentified organic compounds when it is heated excessivelyor burned. WEAR SELF-CONTAINED BREATHING APPARATUS. EXTINGUISHING MEDIA: Water fog, dry chemical, alcohol foam, or carbon dioxide. FIRE FIGHTING INSTRUCTIONS: Do not breathe fumes. Wear complete firefighting gear, including
protective gloves, eye protection and self-contained breathing apparatus. Wash clothingbefore reuse. AMVAC CHEMICAL CORPORATION Page 4 of 8 AMBUSH® 25W AMVAC MSDS No.: 297_3 ACCIDENTAL RELEASE MEASURES GENERAL: Keep out of water sources. SMALL or LARGE SPILL: Sweep up or vacuum the product into a secure container for reuse or HANDLING AND STORAGE HANDLING: Keep this product cool and dry. Keep container closed. Store away from feed, food,
and drink. Keep away from children and pets. Wash thoroughly after handling this product. STORAGE: Store product in its original container in a cool, dry, locked place out of the reach of EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS: Ventilation should be sufficient to keep the exposure below the TLV.
Use of mechanical or local exhaust systems is recommended when dust formation is possible. RESPIRATORY PROTECTION: For exposures outdoors that may exceed the TLV, a Dust/Mist
filtering respirator (MSHA/NIOSH approval number prefix TC-21C) is required . Forexposures in enclosed areas that may exceed the TLV, a respirator with either an organicvapor-removing cartridge with a prefilter approved for pesticides (MSHA/NIOSH approvalnumber prefix TC-23C), or a canister approved for pesticides (MSHA/NIOSH approvalnumber prefix TC-14G) is required. SKIN PROTECTION: Applicators and other handlers must wear long-sleeved shirt and long pants;
waterproof gloves; and shoes plus socks. Follow manufacturer's instructions for cleaning/maintaining personal protection equipment (PPE). If no such instructions are available, usedetergent and hot water. Keep and wash PPE separately from other laundry. EYE PROTECTION: Safety glasses with sideshields should be used whenever hazardous chemicals
are being handled. Tight fitting chemical goggles should be worn whenever there is a chanceof dusting from the product. OTHER PROTECTION: There should be an eyewash station and a safety shower in the work area. PHYSICAL AND CHEMICAL PROPERTIES Physical State: Appearance: Odor Threshold: AMVAC CHEMICAL CORPORATION Page 5 of 8 AMBUSH® 25W AMVAC MSDS No.: 297_3 PHYSICAL AND CHEMICAL PROPERTIES, cont'd Boiling Point: Crystallization Point: Density: Bulk Density: Vapor Pressure (mm/Hg): Vapor Density: Percent Volatile by Vol: Solubility in Water: Solubility (Other):
Permethrin is soluble in aromatic and paraffinic solvents andalcohols
Partition Coefficient (O/W):
The partition coefficient for Permethrin is 6.1 (log P)
Evaporation Rate: STABILITY AND REACTIVITY CHEMICAL STABILITY (Conditions to avoid): This product is stable under normal storage and use INCOMPATIBILITY: Oxidizing agents. HAZARDOUS DECOMPOSITION PRODUCTS: This product may emit hazardous fumes of
hydrogen chloride, carbon oxides and unidentified organic compounds when it is heatedexcessively or burned. WEAR SELF-CONTAINED BREATHING APPARATUS when theseconditions are present. HAZARDOUS POLYMERIZATION: This product will not polymerize. TOXICOLOGICAL INFORMATION
The following information is available for Permethrin Technical (2) and for the formulation (1):
INGESTION(1): DERMAL(1): INHALATION(2): SENSITIZATION(1): IRRITATION(1): TERATOGENICITY(2): No evidence of teratogenicity has been observed in laboratory testing. MUTAGENICITY(2): No evidence of mutagenicity has been observed in animal testing. AMVAC CHEMICAL CORPORATION Page 6 of 8 AMBUSH® 25W AMVAC MSDS No.: 297_3 TOXICOLOGICAL INFORMATION, cont’d CARCINOGENICITY(2): No evidence of carcinogenicity has been observed. EPA (2004) has
evaluated the carcinogenic potential of Permethrin under its ‘Review Draft of the Guidelinesfro Carcinogen Risk Assessment (1999)’. Permethrin has suggestive evidence ofcarcinogenicity but not sufficient to assess human carcinogenic potential. REPRODUCTIVE TOXICITY(2): No evidence of reproductive toxicity has been observed. TOXICOLOGICALLY SYNERGISTIC PRODUCTS(2): No data is available. ECOLOGICAL INFORMATION GENERAL: This pesticide is extremely toxic to fish and aquatic organisms. Do not contaminate water
when disposing of equipment washwaters. Do not apply directly to water, to areas wheresurface water is present, or to intertidal areas below the mean high water mark. Do not applydirectly adjacent to potable water supplies. This pesticide is extremely toxic to bees, both ondirect application and residues on flowering plants and weeds. Do not spray if bees arepresent. DISPOSAL CONSIDERATIONS PESTICIDE DISPOSAL: Wastes resulting from the use of this product may be disposed on site (by
use according to the label) or at an approved waste disposal facility. Further information canbe obtained from the EPA or the equivalent national, state and local agencies. CONTAINER DISPOSAL: Completely empty bag into application equipment. Then dispose of
empty bag in a sanitary landfill or by incineration, or, if allowed by State and local authorities,by burning. If burned, stay out of smoke. Check with EPA, national, State, and localauthorities for the current regulations applicable to your area. TRANSPORTATION INFORMATION AMVAC CHEMICAL CORPORATION Page 7 of 8 AMBUSH® 25W AMVAC MSDS No.: 297_3 TRANSPORTATION INFORMATION, cont’d PACKAGING
2 lb bags (6/box); 2 water soluble pouches/bag
REGULATORY INFORMATION U.S. FEDERAL REGULATIONS: This product is registered under EPA/FIFRA Regulations as a
RESTRICTED USE PESTICIDE. It is a violation of Federal Law to use this product in anymanner inconsistent with its labeling. Read and follow all label directions. This product isexcluded from listing requirements under EPA/TSCA. SARA TITLE III DATA Section 311 & 312 Hazard Categories: Section 302 Extremely Hazardous Substances: None Section 313 Toxic Chemicals: Permethrin (52645-53-1) - 25% CERCLA/EHS Reportable Quantities (RQ): None STATE REGULATIONS: CALIFORNIA (Proposition 65): None OTHER INFORMATION MSDS Status: Date This Revision: 21 October, 2005 Date Previous Revision: 18 December 2003 Person Responsible for Preparation: Gary A. Braden Reasons for Revision: Changes were made in section 3 and section 11 to include clarification of the
carcinogenic potential of this product. Formatting and spelling corrections were madethroughout the MSDS. AMVAC CHEMICAL CORPORATION Page 8 of 8 AMBUSH® 25W AMVAC MSDS No.: 297_3 OTHER INFORMATION, cont’d DISCLAIMER: This information is provided for the limited guidance to the user. While AMVAC
believes that the information is, as of the date hereof, reliable, it is the user's responsibilityto determine the suitability of the information for its purposes. The user is advised not toconstrue the information as absolutely complete since additional information may benecessary or desirable when particular, exceptional, or variable conditions or circumstancesexist (like combinations with other materials), or because of applicable regulations. Noexpress or implied warranty of merchantability or fitness for a particular purpose or otherwiseis made hereunder with respect to the information or the product to which the informationrelates. ABBREVIATIONS:
American Conference of Governmental Industrial Hygienists
Comprehensive Environmental Response, Compensation, and Liability Act
Federal Insecticide, Fungicide, and Rodenticide Act
International Agency for Research on Cancer
Superfund Amendments and Reauthorization Act
This is the last page of this MSDS. There should be 8 pages.
INTRODUCTION The FW-SMK as a part of the FREEWAVE wireless security system is an advanced, fully supervised SMOKE DETECTOR transmitter. FW-SMK The FW-SMK is photoelectric smoke detector designed to sense smoke, but not gas, heat nor flame. It provides early warning of developing fire by sounding an alarm w ith its built-in alarm horn, and by transmitting a coded alarm signal to a rec
Pulso por un cubano La coherencia política antiterrorista de la Administración Bush está siendo sometida a prueba tras la detención en Miami, forzada por una gigantesca manifestación en La Habana, de Luis Posada Carriles, buscado por Cuba y Venezuela desde hace años acusado de haber atentado en 1976 contra un vuelo de Cubana de Aviación en el que murieron 73 personas, de otros